In the digital era, as the core area of data storage and processing, the stability of the computer room environment is directly related to the efficiency and security of enterprise operations. As an indispensable equipment for maintaining this critical environment, the selection and configuration of computer room air conditioners are particularly important. This article will provide you with a detailed analysis of the selection points and configuration strategies of computer room air conditioners to help you create an ideal high-efficiency, energy-saving, and environmentally friendly computer room environment.

1. Selection of air conditioners in the computer room: multi-dimensional considerations and accurate matching of needs
1. Clarify the scope of application and the heating and cold load
The selection of air conditioners in the computer room must first be determined according to the specific environmental characteristics of the computer room. High-temperature air conditioners need to be selected for high-temperature environments, while high-temperature and heat loads require larger capacity models. Accurate calculation of heating and cooling loads is the basis for ensuring constant temperature and humidity in the computer room.

2. Choice of brand and model
Choosing well-known brands such as Haiwu, Haier, etc. means choosing stable and efficient performance and high-quality after-sales service. In terms of model, factors such as the area of the computer room and the number of equipment should be comprehensively considered to ensure that the selected air conditioner can not only meet the current demand, but also reserve a certain amount of expansion space.

3. Ease of installation and maintenance
Convenient installation and maintenance processes reduce downtime and improve system reliability. Therefore, when choosing, preference should be given to those air conditioning models that are easy to install and maintain.
4. Pay equal attention to energy conservation and environmental protection
With the enhancement of environmental awareness, energy-saving and environmentally friendly machine room air conditioners have become the new favorite of the market. This type of product can not only effectively reduce energy consumption and reduce operating costs, but also establish a green image for enterprises.
2. Air conditioning configuration strategy in the computer room: scientific calculation and reasonable layout
1. Cooling calculation: scientific and rigorous
The calculation of the cooling capacity of the air conditioner in the computer room should comprehensively consider factors such as the area of the computer room and the number of servers. According to the computer room's own cooling capacity of 250W per square meter, the server is calculated at 600W per unit. Through precise calculations, it is ensured that the selected air conditioner can fully meet the cooling needs of the computer room. 100 square meters and 60 units can calculate the cooling capacity of the air conditioner required for the room, which is 100×250w=25kw; The cooling capacity of the air conditioner required to cool the server is 60×600W=36kW; That is, the total cooling capacity of the optional precision air conditioner in the computer room is 25kw+36kw=61kw. When choosing a precision air conditioner in the computer room, there must be a certain margin, and the cooling capacity of the air conditioner is generally selected according to 1.1 times the calculation result. Therefore, the cooling capacity of the precision air conditioner in the computer room that should be selected is 61×1.1=67.1kw.
2. Margin design: to deal with emergencies
In order to cope with special external conditions, such as high temperature weather or sudden increase in equipment, it is recommended to increase the margin by 10% on the basis of the calculation results. This can not only ensure the stability of the computer room environment, but also avoid frequent replacement of air conditioning equipment.
3. Heat generation and humidification configuration
The heat production and humidification capacity of the precision air conditioner in the computer room also need to be configured according to the actual situation. Generally speaking, the heat production of precision air conditioners in the computer room can not be very large, and it is enough to choose according to 150w/㎡. The heat production can be calculated at 150W per square meter, and the humidification amount is determined according to the area of the computer room and humidity requirements. The humidification required for the computer room is generally calculated according to the humidification capacity of 1 kg per 20 square meters of room. The humidification capacity of the precision air conditioner in the computer room is 100÷20=5kg/h.
3. Practical cases: application examples of precision air conditioning in the computer room
Taking a 100-square-meter computer room as an example, through scientific calculations, a precision air conditioner with a constant temperature and humidity computer room model of 68KW was finally selected. The air conditioner has a cooling capacity of 68kw, a heating capacity of 15kw, and a humidification capacity of 5kg/h, which perfectly matches the actual needs of the computer room. Since its operation, it has not only effectively ensured the stability of the computer room environment, but also significantly reduced energy consumption and operating costs, becoming a solid backing for enterprise digital transformation.

The selection and configuration of air conditioners in the computer room is a systematic project that requires comprehensive consideration of many factors. Through the analysis of this article, I believe you have a deeper understanding of the selection and configuration of air conditioners in the computer room. Choosing the air conditioning equipment that suits your computer room needs can not only improve the stability of the computer room environment, but also bring long-term economic and social benefits to enterprises. Let's work together to create a more efficient, energy-saving, and environmentally friendly computer room environment!